华南预防医学 ›› 2015, Vol. 41 ›› Issue (3): 207-212.doi: 10.13217/j.scjpm.2015.0207

• 论著 • 上一篇    下一篇

血清中氧化三甲胺的高效液相色谱串联质谱法测定研究

刘燕1,谭栩颖1,许斌2,王一钦1,唐志红1,朱惠莲1   

  1. 1.中山大学公共卫生学院,广东 广州 510080;2.广州市越秀区疾病预防控制中心
  • 出版日期:2015-06-15 发布日期:2015-06-23
  • 通讯作者: 朱惠莲 E-mail:zhuhl@mail.sysu.edu.cn
  • 作者简介:刘燕(1989—),女,在读硕士研究生,研究方向:胆碱及其代谢物与非酒精性脂肪肝
  • 基金资助:
    国家自然科学基金(81273050);广州市科技计划项目(201300000148)

Measurement of trimethylamine-N-oxide in serum by liquid chromatography tandem mass spectrometry

LIU Yan1,TAN Xu-ying1,XU Bin2, WANG Yi-qin1, TANG Zhi-hong1, ZHU Hui-lian1   

  1. 1. School of Public Health, Sun Yat-Sen University, Guangzhou 510080,China;2.Guangzhou Yuexiu District Center for Disease Control and Prevention
  • Online:2015-06-15 Published:2015-06-23

摘要: 目的建立人血清中胆碱依赖肠道菌群代谢物——氧化三甲胺(TMAO)的高效液相色谱串联质谱法(HPLC-MS/MS)的测定方法,并研究其精密度和稳定性。方法以d9TMAO为内标,血清经乙腈除蛋白后,采用SiO2柱 (2.1 mm × 100 mm,5 μm)、乙腈-甲酸铵(10 mmol/L,pH 3.0)等度洗脱,选择多反应监测模式测定,测定方法的精密度和准确度及不同保存条件下的稳定性。结果本研究方法的检测限和定量限分别为0.003和0.063 μmol/L,线性范围为0.16~ 20.00 μmol/L(r2=0.999 9),不同浓度点的日内变异系数为 2.03%~2.64%,日间变异系数为6.00%~9.94%,回收率为89.5%~103.0%;血清在4 ℃保存时,24 h内TMAO浓度变化在10%以内,72 h后TMAO浓度升高明显,浓度变化为15.85%;血清保存于-80 ℃时,72 h后TMAO浓度变化范围均在10%以内;反复冻融4个冻融循环内浓度变化仍在15%的可接受范围内。结论本研究建立的高效液相色谱串联质谱法检测TMAO的方法具有快速、准确且灵敏的特点,可以满足大样本人群血样检测要求。血液样本保存时应注意保存温度、时间对TMAO浓度的影响。

Abstract: Objective To develop a method for measurement of trimethylamine-N-oxide (TMAO)-microbiota-generated metabolite of choline in serum by stable isotope dilution high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) and to study its accuracy and stability. Methods Proteins in samples were precipitated with three volumes of 10 μmol/L internal standard d9-TMAO in acetonitrile and supernatants were analyzed after injection onto a SiO2 column (2.1 mm×100 mm, 5 μm.) and equilibrated with 30% solution A (10 mmol/L ammonium formate, pH = 3.0) and 70% solution B (acetonitrile). Results Lower limit of detection was 0.003 μmol/L and the lower limit of quantitation was 0.063 μmol/L at linear range of 0.16 - 20.00 mol/L (r2=0.999 9). The intra-batch and inter-batch coefficients of variance were 2.03% - 2.64% and 6.00% - 9.94%, and the recovery rates were 89.5% - 103.0%, respectively. Stability study revealed that the storage temperature and time could affect the concentration of TMAO. TMAO in serum was stable both during storage at -80 ℃ and throughout multiple freeze thaw cycles. Conclusion HPLC-MS/MS assay has characteristics of rapidness, accuracy, precision, and high-throughput nature and can meet the detection requirements for large quantity of blood samples.

中图分类号: 

  • R1